About
ICU patient safety monitoring: 21 hand landmarks for fine-grained behavior detection, dwell-time 4-level alarms, dual-dimension false-positive suppression (ROI + time). MediaPipe + OpenCV.
Developer ToolsREADME_EN.md
OriginalICU Hand Behavior Monitoring System
A patient-monitoring system built on MediaPipe hand landmarks and tiered alarms, running on ordinary USB cameras
The Problem
Patients in ICUs — post-surgery, sedated, or confused — may unconsciously grab and pull at catheters and infusion lines. This is the leading precursor of unplanned extubation (UE), which can be life-threatening. Central monitoring stations cannot watch every bed simultaneously, and nursing rounds leave time windows uncovered.
This system assigns the "watch the hands" job to a camera: when a hand enters the monitored region and keeps performing risky movements, it escalates alarms by dwell time — nurses get alerted before the patient actually pulls the tube, not after.
Runs on ordinary USB cameras. No dedicated hardware.
Key Design Decisions
In a real ICU ward, staff walk in and out constantly, so single-frame detection inevitably false-alarms — and monitors that cry wolf get muted by nurses (a documented clinical problem called alarm fatigue). Most of the design effort here therefore goes into filtering false positives: spatially via ROI, temporally via dwell time.
| Decision | Choice | Why |
|---|---|---|
| Detection paradigm | MediaPipe Hands (21 landmarks), not generic object detectors | Pre-extubation behaviors are fine-grained actions like grasping and tugging. A bounding box says "there is a hand"; only landmark geometry (fingertip closure, joint flexion sequences) can express "currently grasping". And MediaPipe runs real-time on CPU |
| Temporal filtering | Dwell-time thresholds (5 / 10 / 15 / 30s), not single-frame judgment | Routine care (adjusting IV stands, turning patients) briefly enters the frame. Single-frame detection must false-alarm; requiring sustained duration filters transients naturally |
| Spatial filtering | Configurable ROI | Only the region around catheters and lines is judged; staff working zones are excluded |
| Escalated alarms | Four levels with distinct sounds | Maps to clinical urgency: brief suspicion → soft tone; sustained danger → high-priority alert. Nurses can triage response order |
| Concurrency | One thread per camera | OpenCV VideoCapture is blocking IO; thread isolation keeps one failing stream (drop, stall) from dragging down the rest, with auto-reconnect |
Architecture
flowchart LR
A["📷 USB Cameras ×N"] --> B["CameraManager<br/>scheduling · auto-reconnect"]
B --> C["VideoProcessor<br/>OpenCV per-frame"]
C --> D["✋ MediaPipe Hands<br/>21 landmarks"]
D --> E["Behavior Engine<br/>ROI + dwell time"]
E --> F{"Threshold met?"}
F -->|"transient motion<br/>(filtered by time)"| C
F -->|"sustained risk"| G["🚨 4-Level Alarm<br/>5 / 10 / 15 / 30s"]
G --> H["Pygame Audio"]
C --> I["Tkinter Panel<br/>FPS · ROI · theme · alarms"]
Engineering Evolution
The project started as a single-file prototype (processor.py) and was later refactored into a modular package — video processing, camera management, UI, and FPS counting each in their own module. The root processor.py remains as a compatibility layer re-exporting the package's interface, so existing imports kept working.
Features
- Real-time hand landmark tracking (MediaPipe Hands), CPU real-time
- 4-level alarms at 5 / 10 / 15 / 30s dwell thresholds, all configurable
- Multi-camera parallel processing with auto-reconnect
- Customizable ROI excluding staff working zones
- Live FPS / camera status / resource panel
- Automatic day/night theme switching (dimmer UI for night wards)
Performance
Single camera · 720p · CPU inference (measured 2025-03):
| Metric | Value |
|---|---|
| Processing latency | < 50 ms |
| CPU usage | < 30% |
| Memory | < 500 MB |
| Gesture recognition accuracy | > 95% |
Quick Start
git clone https://github.com/Trueysh/ICU_Mediapipe.git
cd ICU_Mediapipe
pip install -r requirements.txt
python main.py
Requires Python 3.9+, a 720p+ USB camera, and opencv-python / mediapipe / pygame / numpy. Works on Windows 10/11, Ubuntu 20.04+, macOS 10.15+.
Roadmap
- GPU inference acceleration (TensorRT / OpenVINO)
- Multi-bed wall view
- Alarm event statistics & export (nursing-record integration)
- Config import/export
Author
Yu Shenghui (@Trueysh) — LLM application engineer, 4 years in medical AI (2021–2025), now focused on RAG and AI Agents. More projects on my GitHub profile.
License
MIT — see LICENSE.
中文版:README.md